Test of ladders in MIPOT

 

Download the data base (Last update 11-06-03):

 

Analysis on 99 Ladders from M3000 to M3099

AC Test

4 AC capacitors value before and after the encapsulation

Steady current after the discharge of the AC capacitor before and after the encapsulation

 

Strips Tested: 38016

Unexpected bad strips found: 10 (1 Ac AL Open; 9 Coupling short) 

 

IV Test

Ladder leakage current @50V before and after encapsulation

Ladder leakage current @150V before and after encapsulation

I@50V       Mean: 562nA  Dev: 98nA

I@100V    Mean: 700nA  Dev:120nA

I@150V    Mean: 812nA   Dev:159nA

I@200V   Mean: 1013nA  Dev:646nA

CV Test

Ladder bulk capacitance at 150V before and after encapsulation

 

Ladder depletion voltage before and after encapsulation

 

MIPOT encapsulation detail

 

back